ZG200
Ignitor for lamps rated 15W to 250W
Key Benefits
- Compact size
- Lamp power range of 15W to 250W
- Maximum Current of 4A, Temporary over current of 7.5A <90s
- HBX76 igniter on board
Target Hansmann Ballasts
| Ballast | (XX) |
| ER200 |
AC |
| ERF200 |
AC |
| ELDC 2.31 (i) |
DC |
| EBM3X1 (i) |
AC |
Product Specification
Technical Data
| Maximum current |
5A |
| Temporary over current < 90s within a period of 5 minutes |
7.5A |
| Ignition voltage: |
+/- 14kV |
| Input voltage range |
AC-DC 0-300 V / threshold for ignition > 150V |
| Operation mode |
Symmetrical |
| Ignition mode control |
Self stopping ignitor ca. 2 sec. |
| Pulse rate |
Approximately 100/sec. |
| Repetition rate |
depend on ballast |
| Case temperature |
70°C max |
| Cable length |
HV to lamp 30 cm max. for hot re-ignition (50 cm cold) LV from ballast, limitation according to ballast spec. |
| Dimensions (H x W x L) |
22 x 44 x 53 mm |
| Weight: |
86g |
| Connectors |
4 x M2.5-screw connection |
Input and output terminals are electrically connected (plus from ballast to plus to lamp and minus from ballast to minus to lamp). The ignition pulses are superimposed on input voltage.
CAUTION:
SAFETY
All primary wiring must meet all local national safety regulation.
Specification subject to change without prior notice!