Get Adobe Flash player

ZG1202

Ignitor for lamps rated 70W to 2000W



IKey Benefits

  • Compact size
  • Lamp power range of 70W to 2000W
  • Maximum Current of 15A, Temporary over current of 18A <90s


  • Target Hansmann Ballasts

Ballast (XX)
ER1200 AC
ERF1200 AC
ELDC 2.31 (i) DC
EBM3X1 (i) AC
EBM801 AC
EBM801 DC DC
TFC 1200 AC
TFC 2000 AC
ULD 1500 AC


Product Specification



Technical Data

Maximum current 13A
Temporary over current < 90s within a period of 5 minutes 20A
Ignition voltage: +/- 15kV
Input voltage range AC-DC 0-300 V / threshold for ignition > 150V
Operation mode Symmetrical
Ignition mode control Self stopping ignitor ca. 2 sec.
Pulse rate Approximately 100/sec.
Repetition rate depend on ballast
Case temperature 70°C max
Cable length HV to lamp 30 cm max. for hot re-ignition (50 cm cold) LV from ballast, limitation according to ballast spec.
Dimensions (H x W x L) 27 x 68 x 83 mm
Weight: G
Connectors 4 x M3-screw connection
Input and output terminals are electrically connected (plus from ballast to plus to lamp and minus from ballast to minus to lamp). The ignition pulses are superimposed on input voltage.


CAUTION:



SAFETY

All primary wiring must meet all local national safety regulation..



Specification subject to change without prior notice!


Previous page: ZG501