Get Adobe Flash player

EBM801

Ballast for Metal Halide AC - Lamps or DC - Lamps Short Arc lamps rated 400W to 850W*

For Power beyond 700W, input voltage must be min 110V


Key Benefits

  • Compact size
  • Wide range input voltage
  • Two built-in cooling fan


Target Lamps

ManufacturerType
OSRAM

HMI 400/575
HMP 400/575
VIP 273/400
HTI 300/400/600
HSR 400/575/700
HSD 400
NAV 3500/400/600
HQI 400
HBO 350/500

Philips equivalent to OSRAM lamps


Product Specification



Input Data

Nominal OperationNominalTolerance
Input Voltage AC (V) 100 - 240 90 - 264
Input Voltage DC (V) 100 - 300 90 - 340
System Wattage (W) --- 400 - 950*
Input Current (A) --- 2 - 10*
Line Frequency (Hz) 50/60 47 - 63
Power Factor (1) 1.0 0.93 - 1.0
Depends on lamp select.


Lamp Output Data

IgnitionNominalToleranceRemarks
Ignition Voltage with ZG 20 Xe +/- --- No built- in ignitor
Ignition Time (sec) 1 0.9 - 1.1 dynamical
Automatic restart counter (1) 5 --- attempts
Nominal Operation NominalTolerance
Lamp Voltage (V) 35 - 140 +/-5%*
Lamp Wattage (W) 400, 500, 575, 600, 700, 800, 850 +/-2%
Lamp Current (A) 3 - 12 Depend on select
*Depends on lamp select. Presetable


Lifetime Data

SymbolNominalToleranceRemarks
Ballast Lifetime t Life 25.000 >25.000 acc. to MIL HDBK for nominal operation


Miscellaneous

Nominal OperationNominalTolerance
Efficiency at230V

at110V
45

55
---
Ambient Temperature (°C) +25 0 - +50
Max. Temperature at test poin(°C) +90 +85 - +95


Cooling Recommendations

This unit has two integrated fans, to ensure thermal reliability for most applications. Nevertheless, it is possible to remove these fans and replace them by an external one when the actual application needs to have special requirements. In all cases, a temperature test should be done in the final assembled end product. There is a temperature test point at the heat sink which is located between the two fans. Temperature should not exceed 70°C. Temperature overload protected by an internal temperature switch at 90°C(+/-5°C).



Environmental Requirements

  • Storage Temperature Range -20°C to +50°C
  • OperationTemperature Range - 0°C to +60°C
  • Humidity Range non condensing 20% to 95%
  • Altitude (operating) 0 ft to 10,000 ft
  • Altitude (not operating) 0 ft to 40,000 ft


CAUTION:



SAFETY:

For Continued Protection Against Risk of Fire, Replace Only with same Type and Rating of Fuse! The fuse has to be placed external! T10A L250V

Specification subject to change without prior notice!


Previous page: EBM3X1