EBM801
Ballast for Metal Halide AC - Lamps or DC - Lamps Short Arc lamps rated 400W to 850W*
For Power beyond 700W, input voltage must be min 110V

Key Benefits
- Compact size
- Wide range input voltage
- Two built-in cooling fan
Target Lamps
| Manufacturer | Type |
|---|---|
| OSRAM |
HMI 400/575 |
| Philips | equivalent to OSRAM lamps |
Product Specification
Input Data
| Nominal Operation | Nominal | Tolerance |
|---|---|---|
| Input Voltage AC (V) | 100 - 240 | 90 - 264 |
| Input Voltage DC (V) | 100 - 300 | 90 - 340 |
| System Wattage (W) | --- | 400 - 950* |
| Input Current (A) | --- | 2 - 10* |
| Line Frequency (Hz) | 50/60 | 47 - 63 |
| Power Factor (1) | 1.0 | 0.93 - 1.0 |
Depends on lamp select.
Lamp Output Data
| Ignition | Nominal | Tolerance | Remarks |
|---|---|---|---|
| Ignition Voltage with ZG 20 Xe | +/- | --- | No built- in ignitor |
| Ignition Time (sec) | 1 | 0.9 - 1.1 | dynamical |
| Automatic restart counter (1) | 5 | --- | attempts |
| Nominal Operation | Nominal | Tolerance | |
| Lamp Voltage (V) | 35 - 140 | +/-5%* | |
| Lamp Wattage (W) | 400, 500, 575, 600, 700, 800, 850 | +/-2% | |
| Lamp Current (A) | 3 - 12 | Depend on select |
*Depends on lamp select. Presetable
Lifetime Data
| Symbol | Nominal | Tolerance | Remarks | |
|---|---|---|---|---|
| Ballast Lifetime | t Life | 25.000 | >25.000 | acc. to MIL HDBK for nominal operation |
Miscellaneous
| Nominal Operation | Nominal | Tolerance |
|---|---|---|
| Efficiency at230V at110V |
45 55 |
--- |
| Ambient Temperature (°C) | +25 | 0 - +50 |
| Max. Temperature at test poin(°C) | +90 | +85 - +95 |
Cooling Recommendations
This unit has two integrated fans, to ensure thermal reliability for most applications. Nevertheless, it is possible to remove these fans and replace them by an external one when the actual application needs to have special requirements. In all cases, a temperature test should be done in the final assembled end product. There is a temperature test point at the heat sink which is located between the two fans. Temperature should not exceed 70°C. Temperature overload protected by an internal temperature switch at 90°C(+/-5°C).
Environmental Requirements
- Storage Temperature Range -20°C to +50°C
- OperationTemperature Range - 0°C to +60°C
- Humidity Range non condensing 20% to 95%
- Altitude (operating) 0 ft to 10,000 ft
- Altitude (not operating) 0 ft to 40,000 ft
CAUTION:
SAFETY: